This is the full list of what the platform does today, in the order you will meet it in the app. Features marked add-on are switched on per customer.
Core monitoring plus modules
Every plan includes core monitoring: overview, real-time, trends, topology, alerts, users and the mobile app. The modules below answer the questions that cost the most.
Max demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuilding
PF as billed, this month0.96No penalty
Installed550 kvar
Bank output vs expected92%Check stage 7
Suggested size600 kvar
Power factor per billing month (0.80 to 1.00), penalty below 0.90
Stage plan
4×5, 4×10, 2×15, 2×20, 4×30 kvar, 7% detuned
Example figures
See your site
Overview
The first page after sign-in, on web and mobile
The day at a glance for the whole customer: what you have used, what it cost and whether everything is reporting.
Consumption today and this month, today's peak load, and the hour-by-hour load of today
Estimated carbon footprint today and this month, and the CO₂ your solar saved
Shortcuts into topology, real-time and the main meter's figures
Favourite devices marked by you appear first
Solar customers can open straight on their solar page
ems.zainergy.com
OverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSetting
Live: all 28 meters sending
Consumption today18,420 kWh+3.1%
Peak today1,330 kW
Power factor0.97Above 0.95
Cost todayRs 1.02 M
Load today, kW per hour
Energy sources
Grid 62%
Solar 30%
Genset 8%
Carbon footprint
8.9 t
CO₂ today, 2.1 t avoided by solar
Example figures
Real-time monitor
Any meter, refreshed every minute
Line and phase voltages, currents, kW, kvar, kVA, power factor and frequency per phase
Import and export energy counters, and THD where the meter measures it
Device information as on the meter: model, address, gateway, last reading time
ems.zainergy.com
OverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSetting
Main incomer, updated every minute
Voltage L1 / L2 / L3231 V229 / 232 V
Current1,842 A
Active power1,214 kW
Power factor0.9750.0 Hz
Phase voltages, last 40 minutes
Device
Model
Elster ME237H
Gateway, address
ZG-…288C, 1
Last reading
12 s ago
Example figures
Historical trend
Any reading, any day or range your plan includes
Charts of any reading over a day, a week, a month or your own range
Energy per hour, day or month worked out from the meter's own counter
A table under every chart, with a CSV download for Excel
ems.zainergy.com
Real-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverview
DayWeekMonthRangeCSV
Energy, October14,860 MWh
Highest day668 MWh
Lowest day212 MWhSunday
Energy per day, MWh
Table
Date
MWh
30 Oct
571
31 Oct
602
Example figures
Topology
Your single-line diagram as a live tree
Incomers, main panels, sub panels and loads in the order you set, each with its live load. Follow the energy from the transformer down to a single machine and see where it goes.
ems.zainergy.com
TrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-time
Single-line diagram, live load
Example figures
Building in 3D
For customers with a 3D model of the site
Your building as a 3D model you can turn and zoom, with each floor or zone coloured by its load and pins on the meters. Click a zone to open its figures. The values update live.
ems.zainergy.com
TopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrend
LowHigh
Load per floor, live
Roof plant210 kW
Floor 774 kW
Floor 6152 kW
Floor 596 kW
Floor 4118 kW
Floor 3164 kW
Floor 2128 kW
Floor 1142 kW
Ground floor186 kW
Total 1,270 kW
Example figures
Tanks, flow and sensors
For devices other than energy meters on the same gateway
Tank level with a tank drawing, volume and fill percentage
Flow rate and totalised flow
Temperature, humidity and other sensors with dials, today's lowest and highest, and graphs
Drives (VFDs), smart breakers and PV string monitors read from their own Modbus registers
ems.zainergy.com
OverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSetting
Water tank 1
68%
54,400 of 80,000 litres
Flow and sensors
Flow, boiler feed
12.4 m³/h
Totalised today
186 m³
Cold store temperature
-18.2 °C
Humidity, spinning hall
55%
Compressor drive
48.6 Hz
Example figures
Status
Which devices are sending and when each last reported, the quality of each gateway's connection, and the storage your readings use.
ems.zainergy.com
OverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSetting
Devices sending27 of 281 silent
Gateways3
Storage used1.8 GBof 5 GB
Gateways
Gateway
Panel
Last sent
Signal
ZG-…288C
Main LT panel
12 s
Strong
ZG-…A9B8
Utilities
48 s
Good
ZG-…3F10
Weaving
7 min
No data
Example figures
Cut the bill
Maximum demand
For every customer, on any meter
Maximum demand charges are set by your highest 30-minute block of the billing month. This page shows every block and helps you keep the next one down.
30-minute MDI for any meter and time range, and the peak of each billing month from your own reading day
Ten highest blocks of the period, red above your target and green under it
Block running now: a live box that turns red while the block heads over the target
Save a target as an alert: the running block is projected every minute and a warning appears at the top of the app before the block closes
MDC and demand cost from your tariff
ems.zainergy.com
BuildingMax demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopology
Main incomer: this block is on course to stay under the target
Block running now1,190 kW4 of 30 min
Where it will end1,310 kWUnder target
Target1,350 kW
Peak this billing month1,372 kW
30-minute blocks, today
Ten highest blocks
Time
kW
3 Nov 11:00
1,372
3 Nov 11:30
1,360
2 Nov 15:30
1,331
Example figures
Bills, tariff and cost
Upload your utility bills as PDF, several at once. The platform reads them, keeps them and compares the billed units and demand with your meter
The tariff fills itself from the newest bill: grid rate, fixed charges and other charges
Rates per month for grid, selling to the grid and genset, used for every cost figure in the app
Cost per day, month and meter, so each department sees its share
ems.zainergy.com
PV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plantPower quality
Utility bills, uploaded
Month
Billed kWh
Meter kWh
Difference
September
412,800
409,950
+0.7%
August
438,100
437,620
+0.1%
July
451,300
450,880
+0.1%
Grid rate, peakRs 52.6from the newest bill
Fixed chargesRs 1,250/kW
Cost this monthRs 21.4 M
Example figures
PF plant
For every customer with energy meters
Monitors your power factor improvement plant like the utility bills it, and tells you whether it is the right size.
Performance: power factor as billed per billing month, time in each PF band, leading PF, peak kVA and the penalty it caused
Bank output against what the installed kvar should give at the measured voltage
Sizing from your own 30-minute blocks: the kvar you need, the design figure, the nameplate at your capacitor voltage and detuning, and a suggested stage plan
A verdict on the installed plant, with THD and the resonance order with your transformer
Penalty estimate on uploaded bills, with the threshold and rate as settings
Plant details kept per supply meter: kvar, stages, reactor, controller, commissioning date
ems.zainergy.com
Max demandPF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuilding
PF as billed, this month0.96No penalty
Installed550 kvar
Bank output vs expected92%Check stage 7
Suggested size600 kvar
Power factor per billing month (0.80 to 1.00), penalty below 0.90
Stage plan
4×5, 4×10, 2×15, 2×20, 4×30 kvar, 7% detuned
Example figures
Power quality
From an installed meter that measures harmonics
The same report a survey with a portable analyzer gives, made from the meter already in your panel, for any period up to 31 days at 5 or 10 minute intervals.
Voltages, unbalance, voltage THD, currents, current THD and TDD, kW, PF, frequency, kvar and kVA
Voltage and current harmonic spectrum up to the 31st
Compliance table against EN 50160 and IEEE 519-2022, pass or fail per item
TDD with its own chart and per-phase statistics against the IEEE 519 limit
Effect on equipment: K-factor, extra copper losses and harmonic current
Active harmonic filter sizing: modules, spare capacity, THD and TDD after the filter, and a static var generator option for power factor
Recommendations and method, printed as a PDF under your name
ems.zainergy.com
PF plantPower qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demand
Voltage THD3.1%Pass
Current THD21%
TDD9.8%Over 8%
Active filter2×100 A
Current harmonics, % of fundamental
Compliance
EN 50160 voltage THD
PASS
IEEE 519 voltage THD
PASS
IEEE 519 TDD
FAIL
Example figures
Solar and net metering
For sites with solar, net metering or gensets
Each site's grid, solar and genset meters added up: import, export, solar self-use and total consumption
PV generation report: each site's solar against what it is expected to make per day, from its installed capacity
Saving from solar in rupees, using your buying and selling rates
Solar inverters read directly over Modbus
ems.zainergy.com
Power qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plant
Solar today3,180 kWh98% of expected
Exported420 kWh
Self-use87%
Saving todayRs 168,000
Grid, solar and genset today
Grid 58%
Solar 36%
Genset 6%
Daily generation against expected
Example figures
Shop timing
For retail chains and offices with set opening hours
Consumption inside opening hours against full load for each site, day by day, and the saving against running at full load.
ems.zainergy.com
Power qualityPV net meteringBillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plant
In shop hours3,920 kWh
Full load4,400 kWh
Saving480 kWh11%
Consumption in opening hours, % of full load
Clifton92%
Gulshan88%
DHA104%
Saddar79%
North97%
Example figures
Act in time
Alerts
Set a value with an allowed plus and minus percentage on any reading of any meter
Checked every minute; open alerts stay in the bar at the top of every page until they clear
Demand alerts warn while the 30-minute block is still running
An Alerts page keeps every alert, newest first
ems.zainergy.com
BillsAlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net metering
2 open alerts: demand over target, a meter silent
Alerts today
Time
Device
Alert
State
13:21
Main incomer
Demand heading over target, 1,377 kW
Open
12:58
Weaving panel
No data for 7 minutes
Open
10:14
Chiller 2
Current above 180 A (+10%)
Cleared
08:02
Main incomer
Voltage L2 below 215 V
Cleared
Example figures
AI report Add-on
Choose a meter, or several to compare, and a period. The platform reads the readings and writes a plain-language report: what happened, what it cost and what to do next. Reports are written for maximum demand, PF plant and power quality.
ems.zainergy.com
AlertsAI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBills
AI report: maximum demand, October
Ask AI
"Kal ka peak kitna tha?" – "Kal ka peak 1,331 kilowatt tha, 3:30 baje."
Example figures
Voice assistant Add-on
Ask your plant questions out loud, in Urdu, English or both: "What was yesterday's peak?" or "Is the capacitor bank working?" The assistant answers from your own readings. Switched on for all users or chosen ones.
Run your account
Sites and site logins
Several sites under one account, with devices grouped by site
A login for one site sees only that site's devices, including ones added later
Your short name, for example "JJ", shown beside your name across the app
Users and roles
Customer users see their own sites; staff can be given several customers
Forgot your password? A new one arrives by email; the old one keeps working until the new one is used
Only administrators change meters and settings, so your figures stay the same for everyone
Names and hierarchy
Name every device your way and place it under site, building, panel and feeder. Fill the list in Excel or CSV and load it in one go. The topology follows the hierarchy you set.
ems.zainergy.com
AI reportSettingOverviewReal-timeTrendTopologyBuildingMax demandPF plantPower qualityPV net meteringBillsAlerts
DevicesAlertsCustomerExcel
Your names and places
Name
Placed under
Type
#
Main incomer
Site 1 > Main LT
Energy meter
1
Spinning
Site 1 > Main LT > Spinning
Energy meter
2
Chiller 2
Site 1 > Utilities
Power analyzer
7
Water tank 1
Site 1 > Utilities
Level
12
Example figures
Your look and brand
Dark or light, with a choice of colours for the page and charts. Partners and large customers can have their own name, logo and web address. See partners.
Data history
Readings are never deleted. Your plan sets how far back you can look: 12 months on Pro, 24 months on Pro Plus. See plans.